Noise Characterization and Reduction Techniques of Multiple Axial Fans Unit

Authors

  • Nadim Arafa University of Ontario Institute of Technology
  • Atef Mohany University of Ontario Institute of Technology

Abstract

Experimental noise characterization is performed on a multiple axial fans unit that is used to force air in common house hold or industrial appliances for cooling purposes. The acoustic field generated by the fans unit is mapped at two different conditions; namely, the normal operating condition and the maximum possible rotational speed. It is found that the noise generated by the fan unit has a distinct whistling tone at a frequency that matches the blade passing frequency. The whistling tone may be amplified due to further fluid-sound interactions with the casing of the unit. Hence, several noise reduction techniques are investigated in order to reduce the noise generated from the fans unit, such as annular silencers and L-shaped silencers. Finally, an innovative compact reflective/absorptive silencer is designed and the measurements indicate that it can achieve a noise reduction of 6.3 dBA at normal operating conditions and 9.5 dBA at extreme operating conditions.

Author Biographies

Nadim Arafa, University of Ontario Institute of Technology

Postdoctoral FellowAeroAcoustics and Noise Control LaboratoryUniversity of Ontario Institute of Technology

Atef Mohany, University of Ontario Institute of Technology

Chair and Associate ProfessorDepartment of Automotive, Mechanical, and Manufacturing EngineeringFaculty of Engineering and Applied ScienceUniversity of Ontario Institute of Technology

Additional Files

Published

2017-08-19

How to Cite

1.
Arafa N, Mohany A. Noise Characterization and Reduction Techniques of Multiple Axial Fans Unit. Canadian Acoustics [Internet]. 2017 Aug. 19 [cited 2024 Nov. 3];45(3):110-1. Available from: https://jcaa.caa-aca.ca/index.php/jcaa/article/view/3088

Issue

Section

Proceedings of the Acoustics Week in Canada