Vibration Reduction Of Vertical Pumps - A Case History

Auteurs-es

  • M. M. Osman Ontario Hydro, Power Equipment and Energy Studies Dept, 700 University Avenue, H14 Toronto, Ontario M5G 1X6

Résumé

Vertical pumps are susceptible to vibration problems partly due to their "one-point" attachment to the foundation. A case history of high vibrations of a vertical pump and a design modification to remedy it are presented here. Vibration measurements were carried out to identify the causes for the high, unacceptable vibration levels and to assess the effectiveness of the proposed design modification.

Fichiers supplémentaires

Publié-e

1980-10-01

Comment citer

1.
Osman MM. Vibration Reduction Of Vertical Pumps - A Case History. Canadian Acoustics [Internet]. 1 oct. 1980 [cité 22 nov. 2024];8(4):7-10. Disponible à: https://jcaa.caa-aca.ca/index.php/jcaa/article/view/445

Numéro

Rubrique

Articles techniques