Echo suppression in a large fan shaped auditorium

Auteurs-es

  • J. O'Keefe Aercoustics Engineering Ltd, Toronto, Canada

Mots-clés :

Acoustic variables measurement, Auditoriums, Echo suppression, Stages, Diffusers, Scale model

Résumé

A 1:50 scale model was built to investigate ways to eradicate the echo. Scale model measurements were carried out using the MIDAS small scale modelling techniques. Four different diffusers were designed. The diffusers were fastened to the walls. Listening tests indicate that the side wall echo has been eliminated.

Fichiers supplémentaires

Publié-e

1997-09-01

Comment citer

1.
O’Keefe J. Echo suppression in a large fan shaped auditorium. Canadian Acoustics [Internet]. 1 sept. 1997 [cité 13 août 2024];25(3):23-. Disponible à: https://jcaa.caa-aca.ca/index.php/jcaa/article/view/1092