Selecting Suitable Noise Control for Mine Return Air Raise Systems

Authors

  • Andrew Dobson HGC Engineering
  • William Gastmeier HGC Engineering

Abstract

Recent measurements and observations suggest that moisture and particulate drawn through the return air raise systems which ventilate underground mines can cause rapid clogging and degradation of the outlet silencers, if not properly accounted for in the design of the system. The implications of this are multifaceted, and include significant economic, environmental, and residential annoyance concerns. This paper will present measured source and receptor based sound level data collected as part of a residential complaint investigation, outline specific elements which can be considered when designing a return air system to optimize the potential of the noise control equipment, and will examine the feasibility of implementing atypical noise control methods.

Author Biography

Andrew Dobson, HGC Engineering

Senior Consultant, Associate

Additional Files

Published

2016-08-24

How to Cite

1.
Dobson A, Gastmeier W. Selecting Suitable Noise Control for Mine Return Air Raise Systems. Canadian Acoustics [Internet]. 2016 Aug. 24 [cited 2024 Apr. 23];44(3). Available from: https://jcaa.caa-aca.ca/index.php/jcaa/article/view/2944

Issue

Section

Proceedings of the Acoustics Week in Canada