Determination of flanking transmission and field sound transmission loss in wood-framed constructions using intensity methods

Auteurs-es

  • T.R.T. Nightingale Acoust. Lab., Inst. for Res. in Constr., Nat. Res. Council Canada, Ottawa, Ont., Canada

Mots-clés :

acoustic intensity measurement, acoustic wave absorption, acoustic wave transmission, losses, structural acoustics, wood, field sound transmission loss, wood-framed constructions, acoustic intensity, flanking transmission, double wood stud construction, plywood floor, intensity measurements

Résumé

The method of acoustic intensity is used to determine the presence and magnitude of flanking transmission in a common double wood stud construction. Two construction specimens are considered. The first, without a construction fault, represents the ideal case in which there should be no flanking. The second specimen has a potentially common construction fault. The plywood floor decking of the upper rooms is continued across the party line. The results of the intensity measurements are presented for the various surfaces. Difficulties encountered when using the intensity technique in the presence of flanking transmission are also discussed