Abstract

This is a study of the sound attenuation of acoustic shields used in a symphonic orchestra to protect musicians’ hearing. The shields were placed right behind the ears of players who had the highest exposure to the sound of instruments in the pit of the auditorium in the Four Seasons Centre for Performing Arts in Toronto. In order to measure the attenuation of the shield, noise dosimeters were located in front and behind the shields. The field attenuation of each shield was calculated as the difference between the Leq measured on both dosimeters. Two types of shields, Wenger and Manhasset, were measured. The overall attenuation was found to be -0.48 dBA.

Author Biography

Yang Luo, Ryerson University

Undergraduate Research Assistant at Ryerson University, School of Occupational and Public Health

Additional Files

Published

2018-03-13

How to Cite

1.
Luo Y, Pham A, Behar A, Mosher S, Abdoli M. Acoustic Shields - A Study of Field Attenuation. Canadian Acoustics [Internet]. 2018 Mar. 13 [cited 2024 Nov. 24];46(1):29-35. Available from: https://jcaa.caa-aca.ca/index.php/jcaa/article/view/3035