Acceptable party wall sound insulation criteria

Auteurs-es

  • J.S. Bradley Inst. for Res. in Construction, National Research Council, Montreal Rd., Ottawa, Ont. K1A 0R6, Canada

Mots-clés :

Acoustic noise measurement, Houses, Noise abatement, Sound insulation, Walls (structural partitions), Sound transmission losses, Wall sound insulation

Résumé

Results of aggregate response data from a field survey of the sound insulation walls separating multiple unit housing in 3 Canadian cities were analyzed. Only the apparent STC ratings of the walls were considered. Data were aggregated into 8 groups by apparent STC rating. Based on the analysis, it is proposed that an effective STC of 55 is a realistic goal and STC 60 is a more ideal goal for party wall sound insulation.

Fichiers supplémentaires

Publié-e

2001-09-01

Comment citer

1.
Bradley J. Acceptable party wall sound insulation criteria. Canadian Acoustics [Internet]. 1 sept. 2001 [cité 6 mai 2026];29(3):56-7. Disponible à: https://jcaa.caa-aca.ca/index.php/jcaa/article/view/1381

Numéro

Rubrique

Actes du congrès de la Semaine canadienne d'acoustique